FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

1208825002: Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Apr 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
5067784018 Implantable cardioverter defibrillator coronary sinus lead dislodgement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5067788015 Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5067789011 Dislodgement of implantable cardioverter defibrillator coronary sinus lead en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4971211010 Implantable cardioverter and defibrillator coronary sinus lead dislodgement (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5034797016 Implantable cardioverter and defibrillator coronary sinus lead dislodgement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5067784018 Implantable cardioverter defibrillator coronary sinus lead dislodgement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5067788015 Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5067789011 Dislodgement of implantable cardioverter defibrillator coronary sinus lead en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder) Due to Procedure false Inferred relationship Existential restriction modifier (core metadata concept) 3
Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder) Associated with Implantable defibrillator leads true Inferred relationship Existential restriction modifier (core metadata concept) 2
Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder) Associated morphology Malposition (morphologic abnormality) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder) Is a Implanted defibrillator electrode lead displacement true Inferred relationship Existential restriction modifier (core metadata concept)
Dislodgement of implantable cardioverter defibrillator coronary sinus lead (disorder) Associated with Implantable defibrillator true Inferred relationship Existential restriction modifier (core metadata concept) 4

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start