1255968007: Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Nov 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
5150447016 Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5150448014 Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5150498010 Fluoroscopy guided replacement of intrathecal implantable infusion pump and intrathecal catheter en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5150447016 Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5150448014 Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5150498010 Fluoroscopy guided replacement of intrathecal implantable infusion pump and intrathecal catheter en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Is a Replacement of intrathecal implantable infusion pump (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Is a Replacement of intrathecal catheter (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Is a Removal of intrathecal catheter using fluoroscopic guidance true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Replacement - action false Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Subarachnoid space structure (body structure) false Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Direct device Intrathecal implantable infusion pump (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Replacement - action false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Subarachnoid space structure (body structure) false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Direct device Microspinal catheter (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Subarachnoid space structure (body structure) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Surgical replacement - action false Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Direct device Microspinal catheter (physical object) false Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Surgical replacement - action false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Direct device Intrathecal implantable infusion pump (physical object) false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Subarachnoid space structure (body structure) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Subarachnoid space structure (body structure) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Surgical replacement - action true Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Subarachnoid space structure (body structure) true Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Direct device Intrathecal implantable infusion pump (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Method (attribute) Surgical replacement - action true Inferred relationship Existential restriction modifier (core metadata concept) 4
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Subarachnoid space structure (body structure) true Inferred relationship Existential restriction modifier (core metadata concept) 4
Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Direct device Microspinal catheter (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 4

Inbound Relationships Type Active Source Characteristic Refinability Group
Fluoroscopy guided replacement of intrathecal implantable infusion pump and spinal segment of intrathecal catheter Is a True Replacement of intrathecal implantable infusion pump and intrathecal catheter using fluoroscopic guidance (procedure) Inferred relationship Existential restriction modifier (core metadata concept)

This concept is not in any reference sets