Inbound Relationships |
Type |
Active |
Source |
Characteristic |
Refinability |
Group |
dispositif de neurostimulation |
Is a |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Cardiac assist implant |
Is a |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Cardiac transvenous pacemaker, device (physical object) |
Is a |
True |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Implantable defibrillator |
Is a |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Maintenance of battery of intravenous cardiac pacemaker system |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Complete removal of implanted cardiac pacemaker system |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Repositioning of permanent transvenous electrodes (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Replacement of permanent transvenous electrodes |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Reposition of cardiac pacemaker pocket |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Revision of skin pocket for pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Replacement of electronic heart device battery |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Automatic defibrillator procedure (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Implantation of automatic cardiac defibrillator |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of automatic cardiac defibrillator |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Cardiac pacemaker procedure |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Temporary cardiac pacemaker procedure |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Direct temporary cardiac pacemaker procedure |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Insertion of epicardial electrode for temporary cardiac pacing |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Insertion of endocardial electrode for temporary cardiac pacing |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Transoesophageal cardiac pacing procedure |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Transthoracic cardiac pacing procedure |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Permanent cardiac pacemaker procedure |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Insertion of permanent epicardial cardiac pacemaker system |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Maintenance procedure for cardiac pacemaker system (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Reprogramming of cardiac pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Change of cardiac pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of implanted cardiac pacemaker system or components |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of cardiac pacing electrode |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
réinsertion de la pile d'un stimulateur cardiaque |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Disorder of cardiac pacemaker electrode |
Causative agent (attribute) |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Pacemaker electrode infection |
Causative agent (attribute) |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Pacemaker electrode displacement (disorder) |
Causative agent (attribute) |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Pacemaker electrode lead fracture |
Causative agent (attribute) |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Pacemaker electrode lead displacement |
Causative agent (attribute) |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
General maintenance of cardiac pacemaker (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Insertion of temporary cardiac pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Diaphragm pacemaker procedure |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Reimplantation of cardiac pacemaker electrode |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Bundle of His pacing |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Intraventricular pacing |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
complication mécanique due à une électrode d'un stimulateur cardiaque |
Causative agent (attribute) |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
réparation d'une cavité d'un stimulateur cardiaque situé dans la peau et/ou le tissu v |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Implantation of electrode into cardiac atrium, replacement |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Check artificial pacemaker for electrode impedance |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Electronic analysis of internal pacemaker system |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of cardiac pacemaker from epicardium with replacement of atrial and/or ventricular leads |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Replacement of transvenous atrial pacemaker electrode leads |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Cardiac pacing (procedure) |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Demand pacing |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Relocation of cardiac pacemaker pocket to new site in subcutaneous tissue |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
analyse électronique d'une onde ou d'un stimulateur, complète |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Repair of cardiac pacemaker (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Check artificial pacemaker for waveform artefact |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Insertion of intracardiac pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of cardiac pacemaker with replacement by single-chamber device, rate-responsive |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of transvenous electrodes |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of electronic heart device pulse generator |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Electronic wave or pacemaker analysis, remote |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
débridement de la peau ou du tissu subcutané de la poche d'un stimulateur cardiaque |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Replacement of transvenous ventricular pacemaker electrode leads (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Check artificial pacemaker for amperage threshold (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Insertion of permanent atrial pacemaker with transvenous electrodes (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Insertion of permanent pacemaker with transvenous electrodes, AV sequential |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Replacement of electronic heart device, pulse generator |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Repair of pacemaker with replacement of pulse generator |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Temporary insertion of pacemaker into atrium by transvenous route |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of spinal pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Replacement of transvenous atrial and ventricular pacemaker electrode leads |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
3 |
Implantation of electrode into cardiac ventricle, replacement (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Removal of cardiac pacemaker electrodes with replacement |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Implantation of automatic cardioverter/defibrillator, total system |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Electronic analysis of dual chamber internal cardiac pacemaker system with reprogramming |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Electronic analysis of dual chamber internal cardiac pacemaker system without reprogramming |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Insertion of permanent pacemaker with transvenous electrodes, ventricular |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Revision of pacemaker electrode leads |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Removal of automatic implantable cardioverter/defibrillator pads and electrodes |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of spinal pacemaker with synchronous replacement |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of epicardial electrodes |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Implantation of electrode into cardiac atrium and ventricle, replacement (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Removal of electronic heart device battery (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Repair of cardiac pulse generator |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Temporary transcutaneous pacing |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Temporary transcutaneous pacing |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Implantation of diaphragmatic pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of cardiac pacemaker |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Check artificial pacemaker by slew rate check |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Implantation of cardiac temporary transvenous pacemaker system during and immediately following cardiac surgery |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Electrocardiographic recording from artificial pacemaker |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Insertion of permanent transvenous electrodes |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Replacement of electronic heart device, myocardial electrode |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
stimulateur cardiaque peropératoire |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Intra-atrial pacing (procedure) |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Insertion of pacemaker pulse generator |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Removal of epicardial electrodes with replacement of epicardial lead (procedure) |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
3 |
Electro-mechanical dissociation caused by cardiac pacemaker (finding) |
Causative agent (attribute) |
True |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
4 |
Removal of pacemaker electrode leads without replacement |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
3 |
Revision of permanent cardiac pacemaker device |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |
Induction of arrhythmia by electrical pacing |
Using |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Creation of cardiac pacemaker pocket new site in subcutaneous tissue |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
2 |
Electronic analysis of internal pacemaker system, complete |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
|
Repair of pacemaker electrodes |
Direct device |
False |
Cardiac pacemaker |
Inferred relationship |
Existential restriction modifier (core metadata concept) |
1 |