FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

444542000: Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 01-Aug 2024. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2834833015 Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2838590017 Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2834833015 Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2834833015 Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2838590017 Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2838590017 Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode Is a Insertion of single chamber pacing cardioverter defibrillator pulse generator (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode Method (attribute) Insertion (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode Direct device Single chamber pulse generator, device (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode Method (attribute) Insertion (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode Direct device Transvenous electrode true Inferred relationship Existential restriction modifier (core metadata concept) 1
Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode Method (attribute) Insertion (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Insertion of single chamber pacing cardioverter defibrillator pulse generator and transvenous electrode Direct device Biomedical device false Inferred relationship Existential restriction modifier (core metadata concept) 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start