FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

450820006: Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2012. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2917037017 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917043015 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917037017 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2917037017 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917043015 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2917043015 Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Is a Fluoroscopic guidance true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Method (attribute) Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Has intent Guidance intent (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Is a Replacement of device (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Is a Removal of cardiac pacemaker true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Method (attribute) Replacement - action false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Direct device Pacemaker pulse generator, device (physical object) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Indirect device Permanent cardiac pacemaker, device (physical object) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Method (attribute) Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Has intent Guidance intent (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Method (attribute) Surgical replacement - action true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Direct device Pacemaker pulse generator, device (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Indirect device Permanent cardiac pacemaker, device (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of pulse generator of permanent cardiac pacemaker using fluoroscopic guidance Is a Surgical removal (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start