FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

450821005: Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2012. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2917013017 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917046011 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917013017 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2917013017 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917046011 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
2917046011 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Fluoroscopic guidance true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method (attribute) Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Automatic defibrillator procedure (procedure) false Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Replacement of device (procedure) false Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Removal of cardiac pacemaker false Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method (attribute) Replacement - action false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Pacemaker pulse generator, device (physical object) false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Indirect device Implantable defibrillator false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method (attribute) Replacement - action false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method (attribute) Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Pacemaker pulse generator, device (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Indirect device Implantable defibrillator false Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method (attribute) Surgical replacement - action true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Replacement of electronic heart device, pulse generator true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Fluoroscopy guided cardiac pacemaker procedure false Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure true Inferred relationship Existential restriction modifier (core metadata concept) 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method (attribute) Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Pacemaker pulse generator, device (physical object) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Replacement of pulse generator of automatic cardioverter/defibrillator (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Revision status Revision - value (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method (attribute) Surgical action true Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Implantable defibrillator true Inferred relationship Existential restriction modifier (core metadata concept) 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Removal of cardiac pacemaker using fluoroscopic guidance with contrast (procedure) false Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure true Inferred relationship Existential restriction modifier (core metadata concept) 1
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Fluoroscopy of mediastinum true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Fluoroscopy of cardiovascular system (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Imaging of heart (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start