FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

716152007: Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3304906014 Doppler ultrasound scan measurement of segmental blood pressure of artery of lower limb en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
4672982019 Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
4672983012 Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3304896018 Measurement of segmental blood pressure of artery of lower limb using doppler ultrasonography (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3304896018 Measurement of segmental blood pressure of artery of lower limb using doppler ultrasonography (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3304897010 Measurement of segmental blood pressure of artery of lower limb using doppler ultrasonography en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3304897010 Measurement of segmental blood pressure of artery of lower limb using doppler ultrasonography en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3304905013 Doppler ultrasound measurement of segmental blood pressure of artery of lower limb en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3304905013 Doppler ultrasound measurement of segmental blood pressure of artery of lower limb en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3304906014 Doppler ultrasound scan measurement of segmental blood pressure of artery of lower limb en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3304906014 Doppler ultrasound scan measurement of segmental blood pressure of artery of lower limb en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3304906014 Doppler ultrasound scan measurement of segmental blood pressure of artery of lower limb en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
4672982019 Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
4672983012 Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Is a Doppler ultrasonography of artery of lower limb (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Is a Measurement of segmental blood pressure of artery of limb using Doppler ultrasonography (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Has intent Diagnostic intent false Inferred relationship Existential restriction modifier (core metadata concept) 1
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method (attribute) Ultrasound imaging false Inferred relationship Existential restriction modifier (core metadata concept) 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Procedure site - Direct (attribute) Structure of artery of lower limb true Inferred relationship Existential restriction modifier (core metadata concept) 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Using device (attribute) Doppler device false Inferred relationship Existential restriction modifier (core metadata concept) 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method (attribute) Doppler ultrasound imaging - action (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method (attribute) Measurement - action (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Procedure site - Direct (attribute) Structure of artery of lower limb true Inferred relationship Existential restriction modifier (core metadata concept) 1
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Method (attribute) Examination - action true Inferred relationship Existential restriction modifier (core metadata concept) 3
Measurement of segmental blood pressure of artery of lower limb using Doppler ultrasonography (procedure) Procedure site Anatomical or acquired body structure (body structure) true Inferred relationship Existential restriction modifier (core metadata concept) 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start