FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

736700005: Revision of internal cardiac defibrillator lead using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2018. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3521961018 Revision of internal cardiac defibrillator lead using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3521962013 Revision of internal cardiac defibrillator lead using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3521963015 Fluoroscopy guided revision of internal cardiac defibrillator lead en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3521961018 Revision of internal cardiac defibrillator lead using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3521962013 Revision of internal cardiac defibrillator lead using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3521963015 Fluoroscopy guided revision of internal cardiac defibrillator lead en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Is a Revision of automatic implantable cardioverter/defibrillator (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Is a Operation on heart (procedure) true Inferred relationship Existential restriction modifier (core metadata concept)
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Is a Cardiac fluoroscopy false Inferred relationship Existential restriction modifier (core metadata concept)
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Is a Cardiac pacemaker procedure false Inferred relationship Existential restriction modifier (core metadata concept)
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Is a Fluoroscopic guidance false Inferred relationship Existential restriction modifier (core metadata concept)
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Method (attribute) Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier (core metadata concept) 4
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Has intent Guidance intent (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 4
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Procedure site - Direct (attribute) Heart structure false Inferred relationship Existential restriction modifier (core metadata concept) 4
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Revision status Revision - value (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 5
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Method (attribute) Surgical action true Inferred relationship Existential restriction modifier (core metadata concept) 5
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Direct device Endocardial defibrillation lead true Inferred relationship Existential restriction modifier (core metadata concept) 5
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Procedure site - Indirect (attribute) Heart structure true Inferred relationship Existential restriction modifier (core metadata concept) 5
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Revision status Revision - value (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 6
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Method (attribute) Surgical action true Inferred relationship Existential restriction modifier (core metadata concept) 6
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Direct device Implantable defibrillator true Inferred relationship Existential restriction modifier (core metadata concept) 6
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Is a Fluoroscopy guided cardiac pacemaker procedure true Inferred relationship Existential restriction modifier (core metadata concept)
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Method (attribute) Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier (core metadata concept) 2
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Procedure site - Direct (attribute) Heart structure true Inferred relationship Existential restriction modifier (core metadata concept) 2
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Direct device Endocardial defibrillation lead true Inferred relationship Existential restriction modifier (core metadata concept) 2
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Has intent Guidance intent (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 2
Revision of internal cardiac defibrillator lead using fluoroscopic guidance Using substance (attribute) Contrast media (substance) true Inferred relationship Existential restriction modifier (core metadata concept) 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start