FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

78564009: Heart rate measured at systemic artery (observable entity)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2017. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
130365016 Pulse rate en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1234268019 PR - Pulse rate en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
3333097016 Heart rate measured at systemic artery (observable entity) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3333098014 Heart rate measured at systemic artery en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
130365016 Pulse rate en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
130365016 Pulse rate en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
819518016 Pulse rate (observable entity) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
1234268019 PR - Pulse rate en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
1234268019 PR - Pulse rate en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
3333097016 Heart rate measured at systemic artery (observable entity) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3333097016 Heart rate measured at systemic artery (observable entity) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3333098014 Heart rate measured at systemic artery en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3333098014 Heart rate measured at systemic artery en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
356231000195112 pulsazioni it Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
2311001000112 Herzfrequenz gemessen an systemischer Arterie de Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
49331000077114 fréquence du pouls fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
49331000077114 fréquence du pouls fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
356231000195112 pulsazioni it Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
2311001000112 Herzfrequenz gemessen an systemischer Arterie de Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


3 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Pulse rate Is a Pulse characteristics (observable entity) true Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate Is a Cardiovascular measure false Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate Finding site Arterial structure (body structure) false Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate Finding site Cardiovascular system subdivision false Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate Is a Vital signs, function (observable entity) false Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate Is a Heart rate true Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate Scale type (attribute) Quantitative (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 2
Pulse rate Property type Number rate false Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate Characterizes Cardiac process (qualifier value) false Inferred relationship Existential restriction modifier (core metadata concept) 3
Pulse rate This attribute specifies the resulting output of the process characterized by the observed feature. Entire cardiac cycle process false Inferred relationship Existential restriction modifier (core metadata concept) 4
Pulse rate This attribute represents the specific entity on which the observation is directly made, and is used when the observation is indirect, such as when a direct observation is not possible to be done on the entity in which the observable inheres. Systemic arterial structure false Inferred relationship Existential restriction modifier (core metadata concept) 5
Pulse rate This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Number rate true Inferred relationship Existential restriction modifier (core metadata concept) 1
Pulse rate Scale type (attribute) Quantitative (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Pulse rate This attribute represents the specific entity on which the observation is directly made, and is used when the observation is indirect, such as when a direct observation is not possible to be done on the entity in which the observable inheres. Systemic arterial structure true Inferred relationship Existential restriction modifier (core metadata concept) 1
Pulse rate Characterizes Cardiac process (qualifier value) true Inferred relationship Existential restriction modifier (core metadata concept) 1
Pulse rate This attribute specifies the resulting output of the process characterized by the observed feature. Entire cardiac cycle process true Inferred relationship Existential restriction modifier (core metadata concept) 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Normal pulse rate (finding) Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Sinus tachycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Abnormal pulse rate Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Baseline tachycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
tachicardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Pulse slow (finding) Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Labile pulse Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Pulse fast Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Essential paroxysmal tachycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
[D]Tachycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Heart rate Is a False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Pulse rate altered Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 3
Finding of pulse rate (finding) Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Pulse rate stable Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 3
Pulse deficit Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 2
Pulsus alternans Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 2
Pulse missed beats (finding) Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 3
à l'examen : fréquence du pouls Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 3
On examination - pulse rate very slow Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate - bradycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse borderline slow Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate normal Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse borderline fast Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate tachycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate very fast Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate-pulse deficit Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 2
On examination - pulse rate stable Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 2
On examination - pulse rate NOS Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Brachial pulse rate Is a True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Dorsalis pedis pulse rate Is a True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Posterior tibial pulse rate Is a True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept)
Normal pulse rate (finding) Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate very fast Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse borderline slow Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate normal Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse borderline fast Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 2
On examination - pulse rate very slow Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Pulse fast Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Pulse slow (finding) Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
Abnormal pulse rate Interprets True Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate tachycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse rate - bradycardia Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 1
On examination - pulse borderline fast Interprets False Pulse rate Inferred relationship Existential restriction modifier (core metadata concept) 5

This concept is not in any reference sets

Back to Start