FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.4-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

441873006: Percutaneous replacement of aortic valve using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2009. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2818097019 Percutaneous replacement of aortic valve using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2818098012 Percutaneous replacement of aortic valve using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Procedure categorized by device involved false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Fluoroscopic guidance true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Angiocardiography of left heart false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Cardiac fluoroscopy true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Procedure on heart valve false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Replacement procedure true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Using device (attribute) Aortic valve prosthesis false Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Access Percutaneous approach false Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Method Replacement - action false Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Has intent Guidance intent (qualifier value) false Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Procedure site - Direct (attribute) Aortic valve structure true Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Procedure site - Direct (attribute) Aortic valve structure true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Procedure site - Direct (attribute) Aortic valve structure false Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance Access Percutaneous approach false Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance Using device (attribute) Aortic valve prosthesis false Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Replacement of aortic valve true Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Method Surgical replacement - action false Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Transcatheter aortic valve replacement false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Method Surgical replacement - action false Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Using access device (attribute) Vascular catheter false Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Catheter procedure false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Replacement of heart valve with prosthesis (procedure) false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Operation on heart valve false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Replacement of implanted aortic valve false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Fluoroscopy of chest with contrast (procedure) false Inferred relationship Some
Percutaneous replacement of aortic valve using fluoroscopic guidance Access Percutaneous approach true Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Has intent Guidance intent (qualifier value) true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Using substance (attribute) Contrast media (substance) true Inferred relationship Some 2
Percutaneous replacement of aortic valve using fluoroscopic guidance Method Surgical replacement - action true Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Using device (attribute) Aortic valve prosthesis true Inferred relationship Some 1
Percutaneous replacement of aortic valve using fluoroscopic guidance Procedure site - Indirect (attribute) Structure of annulus fibrosus of aorta (body structure) true Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance Method Surgical implantation - action true Inferred relationship Some 3
Percutaneous replacement of aortic valve using fluoroscopic guidance Is a Imaging of heart with contrast (procedure) false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start