FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

1156384006: Pulsed dose rate brachytherapy (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 01-Jun 2025. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4574236016 Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. en Definition Active Entire term case sensitive (core metadata concept) SNOMED CT core
4574086018 Pulsed dose rate brachytherapy (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4574087010 Pulsed dose rate brachytherapy en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4574599012 PDR (pulsed dose rate) brachytherapy en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
7713791000241117 brachythérapie à débit de dose pulsé fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
7713801000241118 curiethérapie PDR (pulsed dose rate) fr Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
7713811000241116 curiethérapie à débit pulsé fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Method Brachytherapy - action false Inferred relationship Some 1
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Using energy (attribute) Radiation false Inferred relationship Some 2
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Has intent Therapeutic false Inferred relationship Some 2
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Using substance (attribute) Radioactive isotope false Inferred relationship Some 1
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Is a Brachytherapy (procedure) false Inferred relationship Some
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Using energy (attribute) Radiation false Inferred relationship Some 1
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Is a High dose brachytherapy (procedure) true Inferred relationship Some
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Method To fix firmly or set securely or deeply in the body. false Inferred relationship Some 1
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Using device (attribute) Brachytherapy device (physical object) false Inferred relationship Some 1
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Method Administration - action true Inferred relationship Some 2
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Using energy (attribute) Ionizing radiation true Inferred relationship Some 2
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Method To fix firmly or set securely or deeply in the body. true Inferred relationship Some 3
Internal or surface radiation treatment that irradiates a treatment volume with high dose rates of radiation (typically greater than 12 Gy/hour) in small fractions (pulses), typically one pulse per hour. Direct device Brachytherapy device (physical object) true Inferred relationship Some 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start