FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

1156708005: Low dose rate brachytherapy using temporary radioactive source (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2021. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4575717017 Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. en Definition Active Entire term case sensitive (core metadata concept) SNOMED CT core
4575706018 LDR (low dose rate) brachytherapy temporary placement en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
4575709013 Low dose rate brachytherapy using temporary radioactive source en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4575710015 Low dose rate brachytherapy using temporary radioactive source (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
7714191000241118 brachythérapie à bas débit de dose avec utilisation d'une source radioactive temporaire fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
7714201000241116 curiethérapie à faible débit de dose avec utilisation d'une source radioactive temporaire fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
7714211000241119 curiethérapie à bas débit de dose avec utilisation d'une source radioactive temporaire fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Has intent Therapeutic false Inferred relationship Some 2
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Using energy (attribute) Radiation false Inferred relationship Some 2
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Using substance (attribute) Radioactive isotope false Inferred relationship Some 1
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Is a Radiation treatment that irradiates a treatment volume with radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). true Inferred relationship Some
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Method Brachytherapy - action false Inferred relationship Some 1
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Using device (attribute) Radioactive implant false Inferred relationship Some 1
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Using device (attribute) Brachytherapy implant false Inferred relationship Some 1
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Using energy (attribute) Radiation false Inferred relationship Some 1
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Is a Temporary implant radiotherapy true Inferred relationship Some
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Method To fix firmly or set securely or deeply in the body. true Inferred relationship Some 1
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Direct device Temporary brachytherapy implant (physical object) true Inferred relationship Some 1
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Method Administration - action true Inferred relationship Some 2
Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. Using energy (attribute) Ionizing radiation true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start