FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

234235000: Implanted defibrillator generator infection (disorder)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
350926016 Implanted defibrillator generator infection en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
622528011 Implanted defibrillator generator infection (disorder) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4993741000241112 infection du générateur du défibrillateur implanté fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implanted defibrillator generator infection Is a Disorder of implanted defibrillator generator true Inferred relationship Some
Implanted defibrillator generator infection Causative agent (attribute) micro-organisme false Inferred relationship Some
Implanted defibrillator generator infection Temporally follows Procedure false Inferred relationship Some
Implanted defibrillator generator infection Finding site Cardiac structure false Inferred relationship Some
Implanted defibrillator generator infection Is a infection selon la localisation false Inferred relationship Some
Implanted defibrillator generator infection Temporally follows Surgical procedure false Inferred relationship Some
Implanted defibrillator generator infection Is a Infectious disease of cardiovascular system false Inferred relationship Some
Implanted defibrillator generator infection Is a infection compliquant les soins médicaux false Inferred relationship Some
Implanted defibrillator generator infection Causative agent (attribute) Infectious agent false Inferred relationship Some
Implanted defibrillator generator infection Temporally follows Automatic defibrillator procedure false Inferred relationship Some
Implanted defibrillator generator infection Temporally follows Intentional, structural alteration of the human body by mechanical, thermal, light-based, electromagnetic, or chemical means, and/or by the incision or destruction of tissues using instruments to cut, burn, vaporize, freeze, suture, probe, or manipulate by closed reductions. false Inferred relationship Some
Implanted defibrillator generator infection Is a Infectious disease of heart false Inferred relationship Some
Implanted defibrillator generator infection Finding site Structure of cardiovascular system subdivision (body structure) false Inferred relationship Some
Implanted defibrillator generator infection Is a Infectious disease of cardiovascular system false Inferred relationship Some
Implanted defibrillator generator infection After Intentional, structural alteration of the human body by mechanical, thermal, light-based, electromagnetic, or chemical means, and/or by the incision or destruction of tissues using instruments to cut, burn, vaporize, freeze, suture, probe, or manipulate by closed reductions. false Inferred relationship Some
Implanted defibrillator generator infection After implantation d'un appareil prothétique false Inferred relationship Some
Implanted defibrillator generator infection Finding site Structure of cardiovascular system (body structure) false Inferred relationship Some
Implanted defibrillator generator infection Associated with Intentional, structural alteration of the human body by mechanical, thermal, light-based, electromagnetic, or chemical means, and/or by the incision or destruction of tissues using instruments to cut, burn, vaporize, freeze, suture, probe, or manipulate by closed reductions. false Inferred relationship Some
Implanted defibrillator generator infection Pathological process (attribute) Infectious process (qualifier value) true Inferred relationship Some 1
Implanted defibrillator generator infection Associated with Implantable defibrillator true Inferred relationship Some 3
Implanted defibrillator generator infection Associated with Procedure false Inferred relationship Some
Implanted defibrillator generator infection Is a Infection associated with cardiac implant (disorder) true Inferred relationship Some
Implanted defibrillator generator infection Due to Procedure false Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start