FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

315612005: Target systolic blood pressure (observable entity)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2021. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
460131015 Target systolic blood pressure en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
712521019 Target systolic blood pressure (observable entity) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Target systolic blood pressure Is a Systolic blood pressure false Inferred relationship Some
Target systolic blood pressure Finding site Structure of cardiovascular system subdivision (body structure) false Inferred relationship Some
Target systolic blood pressure Finding site Systemic arterial structure false Inferred relationship Some
Target systolic blood pressure This attribute refers to the scale of the result of an observation or a diagnostic test. Quantitative value false Inferred relationship Some 3
Target systolic blood pressure Property type Pressure (property) (qualifier value) false Inferred relationship Some
Target systolic blood pressure This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. Structure of cardiovascular system (body structure) false Inferred relationship Some 2
Target systolic blood pressure This attribute specifies the process which the property describes, and on which the property (of this observable) depends. The process can be very general. Systolic phase (qualifier value) false Inferred relationship Some 4
Target systolic blood pressure This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Pressure (property) (qualifier value) true Inferred relationship Some 1
Target systolic blood pressure Is a A target or goal is a parameter whose value is to be achieved, typically through some intervention. true Inferred relationship Some
Target systolic blood pressure This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. Structure of cardiovascular system (body structure) true Inferred relationship Some 1
Target systolic blood pressure This attribute specifies the process which the property describes, and on which the property (of this observable) depends. The process can be very general. Systolic phase (qualifier value) true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

GB English

US English

Back to Start