FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

413025002: Kappa/lambda light chain ratio measurement (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2004. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2468478015 Kappa/lambda light chain ratio measurement (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2474577019 Kappa/lambda light chain ratio en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2478643012 Kappa/lambda light chain ratio measurement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Kappa/lambda light chain ratio measurement (procedure) Is a Kappa light chain measurement true Inferred relationship Some
Kappa/lambda light chain ratio measurement (procedure) Is a Lambda light chain measurement true Inferred relationship Some
Kappa/lambda light chain ratio measurement (procedure) Is a Ratio measurement (procedure) true Inferred relationship Some
Kappa/lambda light chain ratio measurement (procedure) This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Ratio false Inferred relationship Some 3
Kappa/lambda light chain ratio measurement (procedure) Component Immunoglobulin, L chain, kappa false Inferred relationship Some 2
Kappa/lambda light chain ratio measurement (procedure) Method Evaluation - action false Inferred relationship Some
Kappa/lambda light chain ratio measurement (procedure) Component Immunoglobulin, L chain, lambda true Inferred relationship Some 1
Kappa/lambda light chain ratio measurement (procedure) Method Measurement - action false Inferred relationship Some 4
Kappa/lambda light chain ratio measurement (procedure) Method Measurement - action true Inferred relationship Some 1
Kappa/lambda light chain ratio measurement (procedure) This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Ratio true Inferred relationship Some 1
Kappa/lambda light chain ratio measurement (procedure) Component Immunoglobulin, L chain, kappa true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start