Outbound Relationships |
Type |
Target |
Active |
Characteristic |
Refinability |
Group |
Values |
Continuous pulse oximetry (procedure) |
Is a |
Pulse oximetry |
true |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
Using device (attribute) |
Oxygen analyzer |
false |
Inferred relationship |
Some |
2 |
|
Continuous pulse oximetry (procedure) |
Has specimen |
Arterial blood specimen |
false |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
Component |
Hydrogen ion concentration |
false |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
Has intent |
Diagnostic intent (qualifier value) |
false |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). |
The quantity of a substance per volume of the mixture. |
false |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
Method |
Evaluation - action |
false |
Inferred relationship |
Some |
2 |
|
Continuous pulse oximetry (procedure) |
Component |
Oxygen |
false |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
Method |
Measurement - action |
true |
Inferred relationship |
Some |
2 |
|
Continuous pulse oximetry (procedure) |
Method |
Evaluation - action |
false |
Inferred relationship |
Some |
3 |
|
Continuous pulse oximetry (procedure) |
Procedure site |
Structure of cardiovascular system (body structure) |
false |
Inferred relationship |
Some |
2 |
|
Continuous pulse oximetry (procedure) |
Procedure site |
Respiratory tract structure |
false |
Inferred relationship |
Some |
3 |
|
Continuous pulse oximetry (procedure) |
Method |
Measurement - action |
false |
Inferred relationship |
Some |
1 |
|
Continuous pulse oximetry (procedure) |
Procedure site |
Structure of cardiovascular system (body structure) |
false |
Inferred relationship |
Some |
1 |
|
Continuous pulse oximetry (procedure) |
Method |
Measurement - action |
false |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
Component |
Substance |
false |
Inferred relationship |
Some |
|
|
Continuous pulse oximetry (procedure) |
Using device (attribute) |
Pulse oximeter (physical object) |
false |
Inferred relationship |
Some |
1 |
|
Continuous pulse oximetry (procedure) |
Method |
Measurement - action |
false |
Inferred relationship |
Some |
1 |
|
Continuous pulse oximetry (procedure) |
Using device (attribute) |
Pulse oximeter (physical object) |
true |
Inferred relationship |
Some |
2 |
|
Continuous pulse oximetry (procedure) |
Component |
Oxyhemoglobin |
true |
Inferred relationship |
Some |
2 |
|
Continuous pulse oximetry (procedure) |
This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). |
Quantity fraction |
true |
Inferred relationship |
Some |
2 |
|
Continuous pulse oximetry (procedure) |
This attribute refers to the scale of the result of an observation or a diagnostic test. |
Quantitative value |
true |
Inferred relationship |
Some |
2 |
|