Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2007. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2661596010 | Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2675444015 | Endoscopic retrograde renewal of expanding metal stent in bile duct | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
271261000077118 | remplacement endoscopique rétrograde d'un stent métallique d'écartement dans un canal biliaire | fr | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Switzerland NRC maintained Module |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Is a | Replacement of prosthesis in biliary tract (procedure) | true | Inferred relationship | Some | ||
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Is a | A procedure in which an endoscope is used to access the procedure site. | false | Inferred relationship | Some | ||
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Using access device (attribute) | Endoscope | false | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Method | Replacement - action | false | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Direct device | Bile duct prosthesis | false | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Procedure site - Indirect (attribute) | Bile duct structure | false | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Method | Replacement - action | true | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Direct device | Bile duct prosthesis | false | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Procedure site - Indirect (attribute) | Bile duct structure | true | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Using access device (attribute) | Endoscope | true | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Is a | Replacement of stent | true | Inferred relationship | Some | ||
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Direct device | Expandable metal stents are tubular devices made of mesh-like metal that can be inserted into a natural conduit within the body to support and keep open a passageway that has been narrowed or blocked. They are placed into the body in a collapsed state and are either self-expanding or can be expanded using a balloon catheter. | true | Inferred relationship | Some | 1 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Method | Replacement - action | true | Inferred relationship | Some | 2 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Procedure site - Indirect (attribute) | Bile duct structure | true | Inferred relationship | Some | 2 | |
Endoscopic retrograde renewal of expanding metal stent in bile duct (procedure) | Direct device | Bile duct prosthesis | true | Inferred relationship | Some | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets