FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

443170004: Single photon emission computed tomography with computed tomography of brain perfusion (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2835132016 Single photon emission computed tomography with computed tomography of brain perfusion (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2837859014 Single photon emission computed tomography with computed tomography of brain perfusion en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
7524681000241115 PET CT pour évaluation de la perfusion du cerveau fr Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Is a Computed tomography of brain (procedure) true Inferred relationship Some
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Is a Single photon emission computed tomography of brain perfusion (procedure) true Inferred relationship Some
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Procedure site - Direct (attribute) Brain structure true Inferred relationship Some 1
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Method Single photon emission computed tomography - action (qualifier value) true Inferred relationship Some 2
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Method Computed tomography imaging - action (qualifier value) true Inferred relationship Some 1
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Procedure site - Direct (attribute) Brain structure true Inferred relationship Some 2
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Using substance (attribute) Radioactive isotope true Inferred relationship Some 2
Single photon emission computed tomography with computed tomography of brain perfusion (procedure) Is a Single photon emission computed tomography with computed tomography (procedure) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start