Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2836268014 | Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2841167010 | Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2841168017 | Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | Is a | Dialysis fluid creatinine measurement (procedure) | true | Inferred relationship | Some | ||
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | Method | Measurement - action | false | Inferred relationship | Some | 3 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | Component | Creatinine | false | Inferred relationship | Some | 2 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | Has specimen | échantillon de liquide de dialyse péritonéale | false | Inferred relationship | Some | 1 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). | Mass concentration | false | Inferred relationship | Some | 4 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | This attribute refers to the scale of the result of an observation or a diagnostic test. | Quantitative value | false | Inferred relationship | Some | 5 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | Has specimen | Peritoneal dialysate specimen | true | Inferred relationship | Some | 1 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | This attribute refers to the scale of the result of an observation or a diagnostic test. | Quantitative value | true | Inferred relationship | Some | 1 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | Method | Measurement - action | true | Inferred relationship | Some | 1 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). | Mass concentration | true | Inferred relationship | Some | 1 | |
Quantitative measurement of mass concentration of creatinine corrected for glucose concentration in overnight peritoneal dialysis fluid specimen (procedure) | Component | Creatinine | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets