FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

444114007: Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2836171011 Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2838662012 Quantitative measurement of concentration of cryoglobulin in serum specimen en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
2838663019 Quantitative measurement of cryoglobulin in serum specimen en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) Is a Serum cryoglobulin level (procedure) true Inferred relationship Some
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) Method Measurement - action false Inferred relationship Some 3
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) Component Cryoglobulin false Inferred relationship Some 2
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) Has specimen Serum specimen true Inferred relationship Some 1
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Arbitrary concentration (property) (qualifier value) false Inferred relationship Some 4
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) This attribute refers to the scale of the result of an observation or a diagnostic test. Quantitative value false Inferred relationship Some 5
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) Component Immunologic substance false Inferred relationship Some 6
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) This attribute refers to the scale of the result of an observation or a diagnostic test. Quantitative value true Inferred relationship Some 1
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) Method Measurement - action true Inferred relationship Some 1
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Arbitrary concentration (property) (qualifier value) true Inferred relationship Some 1
Quantitative measurement of concentration of cryoglobulin in serum specimen (procedure) Component Cryoglobulin true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start