FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

701553003: Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2021. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3973327018 Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3973328011 Bioabsorbable drug-eluting polymer coated coronary artery stent en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5680081000241119 endoprothèse d'artère coronaire enduite de polymère à élution médicamenteuse biorésorbable fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
5680091000241117 stent coronarien enduit de polymère à élution médicamenteuse biorésorbable fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) Is a Drug-eluting coronary artery stent false Inferred relationship Some
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) Has device characteristic Bioabsorbable false Inferred relationship Some
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) This attribute represents the site where the device is intended to reside in or on the body. Coronary artery structure true Inferred relationship Some
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) Has device characteristic Coated with material (qualifier value) false Inferred relationship Some
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) Has device characteristic Drug-eluting false Inferred relationship Some
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) Is a Bioabsorbable drug-eluting coronary artery stent true Inferred relationship Some
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) This attribute represents the absorbability aspect of an object. Bioabsorbable true Inferred relationship Some
Bioabsorbable drug-eluting polymer coated coronary artery stent (physical object) This attribute represents the material with which an object is coated. Polymer (substance) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start