Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2015. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
3335219013 | A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | en | Definition | Active | Entire term case sensitive (core metadata concept) | SNOMED CT core |
3029065016 | Toe brachial pressure index (observable entity) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
3029141016 | Toe brachial pressure index | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | Is a | Blood pressure | false | Inferred relationship | Some | ||
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | Is a | Vascular measure | true | Inferred relationship | Some | ||
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | Property type | Pressure ratio (property) (qualifier value) | false | Inferred relationship | Some | ||
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. | Digital artery of toe | false | Inferred relationship | Some | 2 | |
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | This attribute is used to specify the denominator of a relative relational property type, such as a ratio of ratios | Structure of brachial artery | false | Inferred relationship | Some | 3 | |
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). | Pressure ratio (property) (qualifier value) | true | Inferred relationship | Some | 1 | |
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. | Digital artery of toe | true | Inferred relationship | Some | 1 | |
A measure of the difference in the systolic blood pressure of the arm and toe calculated by dividing the blood pressure of the toe by that of the arm | This attribute is used to specify the denominator of a relative relational property type, such as a ratio of ratios | Structure of brachial artery | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets