FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

717996004: Biopsy of pelvis using cone beam computed tomography guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2016. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3310836017 Biopsy of pelvis using cone beam computed tomography guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3310837014 Cone beam CT guided biopsy of pelvis en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
3310838016 Biopsy of pelvis using cone beam computed tomography guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a Biopsy of trunk (procedure) false Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a Biopsy using cone beam computed tomography guidance (procedure) true Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a Cone beam computed tomography of pelvis (procedure) true Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Procedure site - Direct (attribute) This structure, also termed the pelvic region, includes the wall, cavity and content of both the true and false pelvis; it consequently incorporates the entire bony pelvis; and inferiorly it is bounded and includes the pelvic diaphragm. The structure incorporates the complete pelvic wall; sacrococcygeal region (including the overlying skin and subcutaneous tissue); the contents of the false pelvic cavity; but in contrast to the 'pelvic segment of trunk' excludes the perineum, external genitalia. false Inferred relationship Some 2
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Procedure site - Direct (attribute) This structure, also termed the pelvic region, includes the wall, cavity and content of both the true and false pelvis; it consequently incorporates the entire bony pelvis; and inferiorly it is bounded and includes the pelvic diaphragm. The structure incorporates the complete pelvic wall; sacrococcygeal region (including the overlying skin and subcutaneous tissue); the contents of the false pelvic cavity; but in contrast to the 'pelvic segment of trunk' excludes the perineum, external genitalia. true Inferred relationship Some 3
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Method Cone beam CT imaging - action true Inferred relationship Some 2
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 2
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Method Biopsy - action true Inferred relationship Some 3
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a Biopsy of abdomen using cone beam computed tomography guidance (procedure) false Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a radiographie pelvienne false Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a Procedure on pelvic region of trunk false Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Procedure site - Direct (attribute) This cross-sectional segment is bounded superiorly by a virtual horizontal plane at the level of the plane traversing the superior boundary of the iliac crest; and inferiorly it extends to the perineum and includes part but not necessarily the entire external genitalia. The segment includes the volume of the true and false pelvic cavities (and also part of the lower abdominal volume below the level of the virtual superior boundary). The volume includes the entire transverse thickness of the body over the longitudinal extent between the superior (upper) and inferior (lower) boundaries including the skin and subcutaneous tissue. The segment relates to the cross-sectional or projectional volume as perceived by transmissive or emissive imaging. true Inferred relationship Some 2
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a Computed tomography and biopsy of pelvis false Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a Procedure on pelvis false Inferred relationship Some
Biopsy of pelvis using cone beam computed tomography guidance (procedure) Is a CT guided biopsy of pelvis true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start