Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2017. Module: SNOMED CT core
Descriptions:
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Cardiac fluoroscopy | true | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | implantation d'un appareil prothétique | false | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Procedure on heart valve | false | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Heart implantation | false | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | intervention avec cathéter | false | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Insertion using fluoroscopic guidance (procedure) | false | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Method | To put in between or into a part(s) of the body. | false | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Direct device | Mitral valve prosthesis | true | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Procedure site - Indirect (attribute) | Mitral valve structure | false | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Using access device (attribute) | Vascular catheter | false | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | false | Inferred relationship | Some | 3 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | false | Inferred relationship | Some | 3 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Procedure site - Direct (attribute) | Mitral valve structure | true | Inferred relationship | Some | 3 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | intervention avec prothèse | false | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | pose d'un dispositif thérapeutique | false | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Fluoroscopic guidance | true | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Implantation of mitral valve prosthesis or synthetic device | true | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Method | To fix firmly or set securely or deeply in the body. | false | Inferred relationship | Some | 1 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Procedure site - Indirect (attribute) | Mitral valve structure | true | Inferred relationship | Some | 1 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Direct device | Mitral valve prosthesis | true | Inferred relationship | Some | 1 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Using access device (attribute) | Vascular catheter | true | Inferred relationship | Some | 1 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Method | Surgical implantation - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Procedure site - Direct (attribute) | Mitral valve structure | true | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Direct device | Mitral valve prosthesis | true | Inferred relationship | Some | 3 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Method | Surgical implantation - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Procedure site - Direct (attribute) | Mitral valve structure | false | Inferred relationship | Some | 1 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Cannula or catheter procedure (procedure) | true | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Is a | Implantation of heart valve | true | Inferred relationship | Some | ||
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | true | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Using substance (attribute) | Contrast media (substance) | true | Inferred relationship | Some | 2 | |
Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Method | Surgical implantation - action (qualifier value) | true | Inferred relationship | Some | 3 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
A surgical procedure where a catheter is passed through a cut in the chest wall and then through the heart wall (transapical) and positioned across the leaking mitral valve. A bioprosthetic mitral valve is then passed through the tube (transcatheter) and placed within the existing surgically implanted mitral valve ring. The aim is to treat the leaking mitral valve without needing to repeat open-heart surgery. | Is a | True | Transcatheter implantation of mitral valve using fluoroscopic guidance (procedure) | Inferred relationship | Some |
This concept is not in any reference sets