FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

723237002: Non-invasive blood pressure (observable entity)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2017. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3335216018 A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff en Definition Active Entire term case sensitive (core metadata concept) SNOMED CT core
3335150017 Non-invasive blood pressure (observable entity) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3335151018 Non-invasive blood pressure en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


4 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff Is a Blood pressure true Inferred relationship Some
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff This attribute refers to the scale of the result of an observation or a diagnostic test. Quantitative value false Inferred relationship Some 2
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff Property type Pressure (property) (qualifier value) false Inferred relationship Some
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. Structure of cardiovascular system (body structure) false Inferred relationship Some 3
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff This attribute specifies the process which the property describes, and on which the property (of this observable) depends. The process can be very general. Cardiac process (qualifier value) false Inferred relationship Some 4
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Pressure (property) (qualifier value) true Inferred relationship Some 1
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. Structure of cardiovascular system (body structure) true Inferred relationship Some 1
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff This attribute refers to the scale of the result of an observation or a diagnostic test. Quantitative value true Inferred relationship Some 1
A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff This attribute specifies the process which the property describes, and on which the property (of this observable) depends. The process can be very general. Cardiac process (qualifier value) true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Non-invasive arterial pressure Is a True A blood pressure which is observed by a non-invasive procedure, one that does not involve entry into a patient such using as a pressure cuff Inferred relationship Some

This concept is not in any reference sets

Back to Start