FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.22-SNAPSHOT  |  FHIR Version n/a  User: [n/a]

76882007: Venous wedge pressure (observable entity)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2017. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
127642011 Venous wedge pressure en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
817651013 Venous wedge pressure (observable entity) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
7111081000241113 pression veineuse bloquée fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module
7111091000241110 pression veineuse occluse fr Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Switzerland NRC maintained Module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Venous wedge pressure Is a Venous pressure false Inferred relationship Some
Venous wedge pressure Is a Venous pressure true Inferred relationship Some
Venous wedge pressure This attribute is used to specify the systematic method of a procedure used to accomplish a specific activity. Wedge pressure technique (qualifier value) true Inferred relationship Some 1
Venous wedge pressure This attribute refers to the scale of the result of an observation or a diagnostic test. Quantitative value false Inferred relationship Some 3
Venous wedge pressure Property type Pressure (property) (qualifier value) false Inferred relationship Some
Venous wedge pressure This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. Venous structure false Inferred relationship Some 4
Venous wedge pressure This attribute specifies the process which the property describes, and on which the property (of this observable) depends. The process can be very general. Cardiac process (qualifier value) false Inferred relationship Some 5
Venous wedge pressure This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Pressure (property) (qualifier value) false Inferred relationship Some 2
Venous wedge pressure This attribute specifies the independent continuant which bears the quality, and on which the dependent quality (of this observable) depends. Venous structure true Inferred relationship Some 1
Venous wedge pressure This attribute is used to specify the type of inherent quality, function, disposition or process characteristic that is being observed or measured. Its values are abstract types of quality (length, odor, concentration) or abstract types of process characteristic (rate, speed, duration), and do not include qualities that are located (length of arm, odor of urine), or given a value (elevated concentration). Pressure (property) (qualifier value) true Inferred relationship Some 1
Venous wedge pressure This attribute refers to the scale of the result of an observation or a diagnostic test. Quantitative value true Inferred relationship Some 1
Venous wedge pressure This attribute specifies the process which the property describes, and on which the property (of this observable) depends. The process can be very general. Cardiac process (qualifier value) true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Venous wedge pressure below reference range (finding) Interprets True Venous wedge pressure Inferred relationship Some 1
Venous wedge pressure within reference range (finding) Interprets True Venous wedge pressure Inferred relationship Some 1
Venous wedge pressure above reference range Interprets True Venous wedge pressure Inferred relationship Some 1
Pulmonary vein wedge pressure (observable entity) Is a False Venous wedge pressure Inferred relationship Some
Pulmonary vein mean wedge pressure (observable entity) Is a False Venous wedge pressure Inferred relationship Some
Pulmonary vein wedge pressure - v wave (observable entity) Is a False Venous wedge pressure Inferred relationship Some
Pulmonary vein wedge pressure - y trough (observable entity) Is a False Venous wedge pressure Inferred relationship Some
Pulmonary vein wedge pressure - x trough (observable entity) Is a False Venous wedge pressure Inferred relationship Some
Pulmonary vein wedge pressure - a wave (observable entity) Is a False Venous wedge pressure Inferred relationship Some
Venous wedge pressure below reference range (finding) Interprets False Venous wedge pressure Inferred relationship Some 1
Venous wedge pressure within reference range (finding) Interprets False Venous wedge pressure Inferred relationship Some 1
Venous wedge pressure above reference range Interprets False Venous wedge pressure Inferred relationship Some 1

Reference Sets

US English

Back to Start